- Contact Person : Ms. Lv Lavin
- Company Name : Henan Sitong Boiler Co., Ltd.
- Tel : 86-371-68097667
- Fax : 86-371-86664359
- Address : Henan,Zhoukou,Sitong Boiler Industrial Park, Taikang County, Zhoukou Ciry, Henan Province, China
- Country/Region : China
- Zip : 461400
Automatic Gas-fired Steam Boiler
Detailed description of steam boiler
Product Features:
1.The burner preset back purging function, improves combustion working conditions, prolongs life
2. The big, unique design, increases the combustion chamber radiation heated area, reduces the volume of the boiler and reduces the NOx emissions,
3. The front and back boiler tube box adopts multistage smoke sealing method, to assure the unleakage of smoke.
4. With large steam space, steam good quality.
WNS Series Horizontal Fuel Oil (Gas) Steam Boiler
Name Model | WNS 0.5 -0.7 -Y(Q) | WNS 1- 0.7 -Y(Q) | WNS 1.5- 1.0 -Y(Q) | WNS2.0 - 1 -Y(Q) | WNS 3- 1.25 -Y(Q) | WNS 4- 1.25 -Y(Q) | WNS 5- 1.25 -Y(Q) | WNS 5- 1.6 -Y(Q) | WNS 6- 1.25 -Y(Q) | WNS 6- 1.6 -Y(Q) | WNS 8- 1.25 -Y(Q) | WNS 8- 1.6 -Y(Q) | WNS 10- 1.25 -Y(Q) | WNS 10- 1.6 -Y(Q) |
Nominal Capacity (t/h) | 0.5 | 1 | 1.5 | 2 | 3 | 4 | 5 | 5 | 6 | 6 | 8 | 8 | 10 | 10 |
Nominal Working Pressure (Mpa) | 0.7 | 0.7 | 1.0 | 1.0 | 1.25 | 1.25 | 1.25 | 1.6 | 1.25 | 1.6 | 1.25 | 1.6 | 1.25 | 1.6 |
Saturated Steam Temperature | 170 | 170 | 184 | 184 | 194 | 194 | 194 | 204 | 194 | 204 | 194 | 204 | 194 | 204 |
Thermal Efficiency of Boiler (%) | 92 | 92 | 92.2 | 92 | 92 | 92.5 | 92.3 | 92.1 | 92 | 92.4 | 92 | 92 | 92.2 | 92 |
Nominal Oil and Gas Consumption (Nm3/h) | 34.5 /42 | 68.5 /82 | 103 /113 | 134 /162 | 201 /243 | 267 /300 | 330 /371 | 331 /372 | 384 /450 | 385 /451 | 523 /588 | 524 /589 | 655 /736 | 656 /737 |
Power Consumption (KW) | 2.96 (2.96) | 4.4/8.9 (3.7) | 4.4/8.9 (5.5) | 7/20.2 (7) | 9.5/22.7 (10.5) | 13/26.2 (13.5) | 14.5/28 (15) | 14.5/28 (15) | 23/45.4 (20.5) | 23/45.4 (20.5) | 24/37.5 (24) | 24/37.5 (24) | 39.5/52 (39.5) | 39.5/52 (39.5) |
Applicable Fuel | Light oil or heavy oil Natural gas or city gas | |||||||||||||
Power Supply (AC) | 380v 50Hz | |||||||||||||
Weight and Size of Maximum Transport Thing (m) | 3.1* 1.9* 1.9 | 4.35* 2.5* 2.33 | 4.36* 1.88* 2.29 | 4.17* 2.1* 2.96 | 4.48* 2.38* 2.96 | 4.9* 2.9* 3.1 | 5.30* 2.40* 3.27 | 5.30* 2.40* 3.27 | 6.14* 2.40* 3.27 | 5.91* 2.40* 3.27 | 6.01* 2.90* 3.37 | 6.01* 2.90* 3.37 | 6.86* 2.9* 3.27 | 6.86* 2.90* 3.37 |
Approx. Weight of Maximum Transporting Thing kg | 4000 | 5800 | 6100 | 6600 | 10000 | 11800 | 13500 | 13500 | 15000 | 15000 | 20000 | 20000 | 24500 | 24500 |
Exhaust Gas Temperature (°C) | 230 | 230 | 230 | 230 | 230 | 230 | 230 | 231 | 230 | 231 | 230 | 231 | 229 | 230 |
Combustion Way | Pressure atomized Micro positive pressure combustion | |||||||||||||
Regulating Mode | Automatic |
Automatic Gas-fired Steam Boiler